FMG Measurement Protocol 1.0

Comparable measurements—or no tested claim.

This protocol defines how Find My Generator plans, records, and publishes independent measurements. Until a real unit completes the required work, its product page remains source-backed analysis—not a hands-on review.

Protocol

Version 1.0

Public and repeatable

FMG Tested badges

0 products

No unearned test claims

Core test areas

5 per family

Tailored to product type

The same evidence standard, adapted to the machine.

Fuel generators, portable power stations, and expansion batteries do different work. Their procedures differ, but every result must be traceable to a controlled condition and an identified instrument.

Output & regulation

Sustained watts, voltage, frequency, starting response, recovery, and protection behavior under disclosed loads.

Runtime & efficiency

Elapsed time and delivered energy tied to a measured fuel quantity, battery state, load, mode, and environment.

Sound profile

A-weighted readings at stated distances, directions, loads, surfaces, wind, and background sound levels.

Recharge & usable energy

Delivered watt-hours, cutoff state, wall input energy, charge time, charge mode, and ambient conditions.

Thermal behavior

Repeatable enclosure and connector temperatures, fan behavior, ambient temperature, and any thermal fault.

Evidence package

Exact unit, instruments, valid runs, raw records, photos, exclusions, limitations, and acquisition disclosure.

Fuel-generator protocol

Output, fuel, sound, and starting behavior.

A correctly rated load bank steps through 25%, 50%, 75%, and 100% of published running output while instruments log watts, voltage, frequency, recovery, faults, and shutdowns.

Runtime results use a measured fuel quantity and delivered watt-hours. Sound is mapped at 7 m / 23 ft on four sides with the load, mode, wind, surface, and ambient level reported.

Cold and heat-soaked starts follow the manual exactly. Attempts, time, temperature, battery state, and any intervention are recorded rather than summarized from memory.

Power-station protocol

Usable energy, recharge, inverter, and heat.

AC discharge tests measure watt-hours delivered to a stated load through normal automatic cutoff. Output steps record regulation, fan behavior, temperature, protection events, and shutdown.

Recharge starts from the documented cutoff state and reports wall input energy, peak input, elapsed time, charge mode, and ambient temperature—not just the screen’s percentage estimate.

Transfer behavior is measured only when that capability is advertised. Expansion batteries are tested with an exact, approved base station, cable or dock, and firmware combination.

Context travels with every number.

A result without a unit, instrument, load, environment, and method is not comparable. The worksheet keeps those fields beside the measurement they qualify.

Exact model, serial number, firmware, sample source, and acquisition terms

Date, elevation, temperature, humidity, wind, surface, and background sound

Instrument model, range, accuracy, and calibration or verification date

Load type, load percentage, fuel or charge state, mode, and warm-up procedure

At least three valid runs for timing, starting, and sound when conditions allow

Original logs, photos, notes, excluded-run reasons, faults, and limitations

Tested-badge gate

The badge follows the evidence.

A protocol-ready page is not a tested page. A product earns the label only after the full record is complete enough for a reader to understand what happened and what the result cannot prove.

An exact production model was physically evaluated.

The date, location, weather, surface, and operating conditions are disclosed.

Loads, fuel or charge state, operating mode, and instruments are identified.

Original results and observations are retained, including failed or excluded runs.

Safety limits, sample size, conflicts, and test limitations are stated.

The published result separates measured values from manufacturer claims.

Commerce cannot buy a tested badge, change a measurement, remove a valid failure, or determine the verdict. Sample source and manufacturer involvement are disclosed with the result.

Safety before data

This is a professional measurement protocol—not a DIY challenge.

Fuel-burning generators must run outdoors, far from structures, openings, and ignition hazards. Qualified personnel must use rated loads and follow the manufacturer’s grounding, bonding, clearance, fuel, battery, and protective-device instructions. Never bypass a safety control or backfeed building wiring. Stop for unstable power, abnormal heat, leakage, damage, smoke, odor, or any fault. Carbon monoxide and emissions claims require suitable professional instruments and procedures beyond a basic product test.